高雅丽, 刘金山, 官利兰, 张新明. 稀盐溶液 - 孔雀绿法测定土壤速效磷的条件选择[J]. 华南农业大学学报, 2014, 35(2): 40-46. DOI: 10.7671/j.issn.1001-411X.2014.02.008
    引用本文: 高雅丽, 刘金山, 官利兰, 张新明. 稀盐溶液 - 孔雀绿法测定土壤速效磷的条件选择[J]. 华南农业大学学报, 2014, 35(2): 40-46. DOI: 10.7671/j.issn.1001-411X.2014.02.008
    GAO Yali, LIU Jinshan, GUAN Lilan, ZHANG Xinming. Selection of conditions for determining soil available phosphoru by dilute salt solution-malachite green method[J]. Journal of South China Agricultural University, 2014, 35(2): 40-46. DOI: 10.7671/j.issn.1001-411X.2014.02.008
    Citation: GAO Yali, LIU Jinshan, GUAN Lilan, ZHANG Xinming. Selection of conditions for determining soil available phosphoru by dilute salt solution-malachite green method[J]. Journal of South China Agricultural University, 2014, 35(2): 40-46. DOI: 10.7671/j.issn.1001-411X.2014.02.008

    稀盐溶液 - 孔雀绿法测定土壤速效磷的条件选择

    Selection of conditions for determining soil available phosphoru by dilute salt solution-malachite green method

    • 摘要: 【目的】探讨用孔雀绿比色法测定 KCl 稀盐溶液浸提磷的适宜条件.【方法】利用标准溶液和不同利用方式的土样,比较不同浸提和显色条件对稀盐溶液 - 孔雀绿法灵敏度和精密度的影响.【结果和结论】浸提适宜条件如下:土水比为 1 g土∶20 mL 水,震荡时间为0.5 h,浸提剂(氯化钾)浓度为0.02 mol·L-1;显色体系中各溶质适宜的最终浓度为:H2SO4 0.48 mo1·L-1、钼酸铵0.024 mol·L-1、孔雀绿质量浓度为0.06 g·L-1.缔合物最大吸收波长为620 nm,ρ(P) 在0~0.2 mg·L-1 范围内符合比耳定律,线性回归方程为A =3.894 3C+0.001(R2 =0.999**,AD620 nm, C 为磷质量浓度),ρ(P)检出限为0.002 mg·L-1.测定结果的准确度和精密度均较高,因此本法适宜于氯化钾稀盐溶液浸提液中磷的测定.

       

      Abstract: 【Objective】The method of available phosphorus characterized by phosphorus extracted in KCl dilute-salt solution was studied. 【Method】 By using standard solution and soil samples from different land use patterns, influences of different conditions during extracting and color-developing stages on the precision and accurancy of dilute-salt solution-malachite green method were studied. 【Result and conclusion】 The optimum conditions for extraction were as follows:1 g soil∶20 mL water for soil-water ratio, 0.5 h for oscillation, and 0.02 mol·L-1 for concertration of KCl extracting solution; The optimum final concentrations of reagents for the color-developing system were as follows: H2SO4 0.48 mol·L-1,(NH4) 6Mo7O24·4H2O 0.024 mol·L-1, malachite green 0.06 g·L-1. The association complex had a maximum absorption wavelength at 620 nm, and Beer’s law was obeyed in the P range of 0~0.2 mg·L-1 with the linear regression equation being A =3.894 3C+0.001(R2 =0.999**)and P detection limit being 0.002 mg·L-1, and the method had high accurancy and precision as well. Thus the method is appropriate to determine phosphorus amount in KCl extracting solution.

       

    /

    返回文章
    返回