刘惠明 张波 陈俊林. 全站仪中间法高程测量及其精度探讨[J]. 华南农业大学学报, 2004, 25(4): 102-106. DOI: 10.7671/j.issn.1001-411X.2004.04.026
    引用本文: 刘惠明 张波 陈俊林. 全站仪中间法高程测量及其精度探讨[J]. 华南农业大学学报, 2004, 25(4): 102-106. DOI: 10.7671/j.issn.1001-411X.2004.04.026
    LIU Hui-ming~1,ZHANG Bo~2,CHEN Jun-lin~1. Investigation into the accuracy of total station elevation surveying using the midway method[J]. Journal of South China Agricultural University, 2004, 25(4): 102-106. DOI: 10.7671/j.issn.1001-411X.2004.04.026
    Citation: LIU Hui-ming~1,ZHANG Bo~2,CHEN Jun-lin~1. Investigation into the accuracy of total station elevation surveying using the midway method[J]. Journal of South China Agricultural University, 2004, 25(4): 102-106. DOI: 10.7671/j.issn.1001-411X.2004.04.026

    全站仪中间法高程测量及其精度探讨

    Investigation into the accuracy of total station elevation surveying using the midway method

    • 摘要: 通过对全站仪中间法高程测量方法的研究,推导了全站仪中间法高程测量的公式,并运用误差传播定律得出高程测量精度公式,分析并计算了各因素对高程测量精度的影响.通过实验验证,认为在一定范围内全站仪代替水准仪进行高程测量可达到三、四等水准测量的要求,并提出提高高程测量精度的几点建议.

       

      Abstract: An elevation survey calculation formula using the total station midway method was deduced. The error transmission principle was applied to derive the formula, and the impact of various factors on elevation survey accuracy were analyzed and calculated. Verified by experiments, it was confirmed that the total station could replace the water level in elevation measurements with the precision meeting the grade three and grade four specifications for water level surveying within certain ranges. Several proposals were presented to increase elevation surveying precision.

       

    /

    返回文章
    返回